3.2.2 Measuring Ring Amplitude
To measure the amplitude, follow these steps:
1). Press the “CURSORS” button to see the Cursor Menu.
2). Press the “Mode” button to select “Manual”.
3). Press the “Type” option button and select “Voltage”.
4). Press the “Source” option button and select “CH1”.
5). Press the “CurA” option button and turn the universal knob to place the
cursor A on the highest peak of the ring.
6). Press the “CurB” option button and turn the universal knob to place the
cursor B on the lowest peak of the ring.
You can see the following measurements on the top of the left screen:
The delta voltage (peak-to-peak voltage of the ringing)
The voltage at Cursor A.
The voltage at Cursor B.
Picture 3.2-2